APsystems EZ1

This page covers what services/apsystems_ez1/apsystems_ez1_mqtt.py publishes for each configured EZ1 microinverter and how it protects the inverter’s flash memory when it changes the power limit. Device services shows where the service sits among the others.

At a glance

One service handles all configured EZ1 microinverters through their local REST API (host, port, default 8050). No cloud account is needed. Each inverter has its own topic prefix, entities and availability.

The service publishes power, daily yield and lifetime yield for string PV1, string PV2 and the total, which makes nine sensors. The lifetime counters have the total_increasing state class, so Home Assistant’s energy dashboard accepts them. There is also a power limit number, an operating status switch and a set of diagnostic sensors that are disabled by default. Where the firmware supports it, those include extended electrical readings: PV input voltage and current, grid voltage and frequency, and temperature.

The EZ1 can store its power limit in flash, and frequent writes wear out flash over time. The service checks for each inverter whether its firmware can keep the limit in RAM instead and adjusts how it writes. For inverters without that support, the service allows at most one write every five minutes, no matter who publishes the command.

Enabling local mode

Out of the box the EZ1 only talks to APsystems’ own cloud (EMA). Switch on the inverter’s local API first, using the official APsystems EZ1 app:

  1. Connect the app directly to the inverter, over Bluetooth or the inverter’s own Wi-Fi access point if it is not on the home network yet, and not through an APsystems cloud account. If the app is signed in to the cloud, sign out first. The Local Mode menu is hidden while a cloud session is active.
  2. Open Settings → Local Mode, enable it and set it to Continuous instead of only the current session, so it survives a reconnect.
  3. Note the IP address shown there. It is the host for the service’s device entry, on port 8050.

The inverter then runs its own HTTP server on that port and no longer needs the cloud for API access. The manufacturer’s EZ1 Local API User Manual walks through it with screenshots.

Entities

Core sensors, polled every cycle:

Entity Topic Unit Notes
PV1 power pv1/power_w W state_class: measurement
PV2 power pv2/power_w W state_class: measurement
Total power total/power_w W Sum of PV1 and PV2
PV1 energy today pv1/energy_today_kwh kWh Resets at midnight
PV2 energy today pv2/energy_today_kwh kWh Resets at midnight
Total energy today total/energy_today_kwh kWh  
PV1 energy lifetime pv1/energy_lifetime_kwh kWh state_class: total_increasing
PV2 energy lifetime pv2/energy_lifetime_kwh kWh state_class: total_increasing
Total energy lifetime total/energy_lifetime_kwh kWh  

Home Assistant’s energy dashboard accepts the lifetime counters as a source because of total_increasing.

Control entities:

Entity Topic Range
Power limit (number) outstation/<id>/set/max_power_limit_w 30–800 W
Operating status (switch) outstation/<id>/set/power_status on/off

Diagnostic sensors are polled on the diagnostic cycle (poll_interval_s × diagnostic_poll_multiplier, by default every 10 minutes) and are disabled by default in Home Assistant:

  • device_info/*: every field the inverter’s getDeviceInfo returns (deviceId, devVer, ssid, ipAddr, minPower, maxPower, isBatterySystem), one sensor per field.
  • alarm/*: every field of getAlarmInfo (offgrid, shortcircuit_1, shortcircuit_2, operating).
  • max_power_flash_default_w: the power limit stored in flash, separate from the RAM based number entity above. See Power-limit handling below. It is only published once the service has confirmed that the inverter supports the RAM/flash split.
  • output_detail/*: extended electrical readings from the undocumented getOutputDataDetail endpoint. v1/v2 are the PV input voltage per string (V), c1/c2 the PV input current per string (A), gv/gf the grid voltage and frequency and t the inverter temperature (°C). Not every firmware provides all of them, see Extended diagnostics below.

Fields the library or the raw API return beyond this list are published as well. _publish_object_fields() walks the whole response object instead of picking keys, so a field added by a firmware update appears as a new diagnostic sensor without a code change.

Power-limit handling: RAM vs. flash

Early EZ1 firmware stores the power limit only in flash, so every setMaxPower call is a flash write. Frequent writes, for example from an automation that adjusts the limit often, wear out the flash. On newer firmware the community found a second, undocumented pair of endpoints, getDefaultMaxPower and setDefaultMaxPower. They read and write a ceiling stored in flash, separately from setMaxPower, which on that firmware only writes to RAM. See Source and credit for where this came from.

The service checks what the connected inverter actually does instead of relying on a firmware version number:

  1. Detection, once per device per service run. On the first diagnostic poll the service calls getDefaultMaxPower. If the inverter answers, the RAM/flash split is available (_ram_mode = True). If the endpoint fails, the inverter is treated as flash only (_ram_mode = False) for the rest of the run and is not probed again.
  2. Raising the flash ceiling once. If RAM mode is confirmed and the default stored in flash is below the inverter’s hardware maximum, the service calls setDefaultMaxPower once to raise it to that maximum. After that, setMaxPower only ever writes to RAM.
  3. Restoring after a restart. The inverter loads the flash value into RAM when it restarts, usually overnight when it powers down at dusk and back up at dawn. Each diagnostic poll compares the RAM value with the last value the service or a user (through the number entity) requested. A difference counts as a reset after a restart, and the service writes the requested value back at once. That is a RAM write and costs no flash write cycle.
  4. Flash only fallback. Inverters without the RAM/flash split write straight to flash. The service itself enforces at least five minutes between two writes (MIN_SECONDS_BETWEEN_POWER_WRITES), so the limit applies to every publisher and not only to the dashboard.

The number.max_power_limit entity always shows the RAM value, which is what the inverter is doing right now. The separate max_power_flash_default_w diagnostic sensor shows the ceiling in flash, so you can see both values.

Extended diagnostics (getOutputDataDetail)

getOutputDataDetail is not part of the inverter’s documented API. The service calls it through the library’s internal request method. Firmware support varies. Some firmware returns all seven fields (v1, v2, c1, c2, gv, gf, t). Some returns grid voltage, grid frequency and temperature but not the PV input voltage and current. That still counts as supported, and those four sensors are simply not published. Firmware that returns none of the seven fields or fails the request is marked unsupported after the first attempt and is not asked again until the service restarts.

Like the RAM/flash detection, the service probes once and remembers the result.

Source and credit

The RAM/flash power limit handling and the getOutputDataDetail diagnostics are based on ideas documented by the community maintained apsystems-ez1-enhanced Home Assistant integration. Both projects talk to the same inverters through the same apsystems-ez1 PyPI package. No code was copied, only the knowledge of how the endpoints behave and the flash protection strategy. See also Third-party sources.

Written for Energy Node v0.9.0 (APsystems EZ1 service v0.4.3).